Skip to main content
Energen Hybrid Systems

Hospitality Industry Hot Water System Solutions

Client DAN Hospitality Private Limited

DAN Hospitality's 5 star Hotel in Bangalore required 50,000 litres of hot water per day at 65°C.

Solution

Consultants: RSP India proposed and installed a new generation indirect type heating solar hybrid hot water system including:

  • 2x 5000 litre hot water storage tanks
  • 4x 84 kW high temperature heat pump
  • 4x 24 m3/hr heat pump circulation pump
  • 4x SS Plate heat exchanger
  • 4x 20 m3/hr secondary circulation pump for PHE
  • 4x 24 litre expansion tanks, closed loop expansion tanks
  • Plumbing in copper +valves+ Accessories+ Insulation & commissioning
  • Centralized control panel for power distribution
  • 4x 5m3/hr return line hot water circulation pumps
  • Timer and temperature panel for control of circulation pump
Hot Water System for DAN Hospitality
Hot Water System setup for DAN Hospitality

Client Le Palace

4 star Hotel, Le Palace in Chennai, India required 12,500 litres of hot water per day at 55°C for rooms, kitchens, bars & restaurants.

Solution

Energen Hybrid Systems proposed and installed a new generation indirect type heating solar hybrid hot water system including:

  • 5x 1000 litre glass enamel twin coil tanks
  • 21x EHS P Collectors (2 Sq mt)
  • 1x Standard solar circulation pump (1 working and 1 standby) with solar controller
  • 2x 20 kW heat pump with inbuilt circulation pump (2W)
  • 3x 24 litres expansion tank (solar + heat pump circuit)
  • Plumbing, Installation and Commissioning
Le Palace
Le Palace Setup

ITC Grand Chola

Client ITC Grand Chola

5 star Hotel, ITC Grand Chola in Chennai, India required 10,000 litres of hot water per day at 55°C for rooms, kitchens, bars & restaurants.

Solution

Energen Hybrid Systems proposed and installed a new generation indirect type only solar hot water system including:

  • 4x 1000 litre glass enamel twin coil tank
  • 48x EHS P Collectors (2 Sq mt)
  • 2x Standard solar circulation pump (1 working and 1 standby) with solar controller
  • 3x 24 litres expansion tank
  • Plumbing, Installation and Commissioning
ITC Grand Chola
ITC Grand Chola set up
Windflower Spa

Client Windflower Spa

Windflower Spa in Pondicherry required 300 litres of hot water per day.

Solution

Prism Consultants proposed and installed an Energen Elite - Indirect type solar thermo siphon hot water system:

Windflower Spa setup

Amari Resort in Maldives

Client Amari Resort in Maldives

Amari Resort in Maldives has 24 individual villas requiring up to 60 liters/day per person or 180 litres of hot water per day per villa.

Solution

Prism Consultants proposed and installed an Energen Elite - Indirect type solar thermo siphon hot water system:

Amari Resort in Maldives